Electrical data  
Rated voltage 600 V
Operating voltage ≤ 125 V (peak value, not for high voltage purposes)
Attenuation of shielding ≥ 40 dB
Insulation resistance ≥ 500 MΩ/km
Unbalanced capacitance to ground 1600 pF/km
Mutual capacitance 52 nF/km (1 kHz)
Characteristic impedance (Ethernet) 100 Ω ±15 Ω (100 MHz)
Loop resistance (Ethernet) ≤ 115 Ω/km
Differential impedance (Ethernet) 250 Ω/km
Unbalanced resistance (Ethernet) 2 %
Dielectric strength wire/wire (Ethernet) 1000 V DC/700 V AC
Dielectric strength wire/shield (Ethernet) 1000 V DC/700 V AC
Signal running time (Ethernet) 5.3 ns/m
Electrical parameters (Ethernet) based on CAT 5
Test voltage ≥ 2000 V
Mechanical data  
Cable structure (Ethernet) star quad
Conductor construction (Ethernet) 7 x 0.25 mm
Cross section (Ethernet) 0.34 mm² (AWG 22)
Min. bending radius, moved 7.5 x outer cable diameter
Min. bending radius, moved in drag chain 15 x outer cable diameter
Min. bending radius, fixed installation 5 x outer cable diameter
Weight 61 kg/km (41 lb/1000 ft)
Outer cable diameter 6.5 mm ± 0.2 mm (0.2559" ± 0.0079")
Conductor material (Ethernet) copper, tinned
Optical covering factor of shielding (Ethernet) ≥ 85 %
Use drag-chain suitable
Max. acceleration 4 m/s²
Max. speed 4 m/s
Max. number of cycles 3 million
Wall thickness of wire insulation (Ethernet) 0.375 mm
Jacket colour yellow
Material jacket PUR (polyurethane)
Wire colour code yellow, orange, white, blue
Wire insulation material PP (polypropylene)
Printing on the jacket BECKHOFF ZB9024 Industrial Ethernet
/ EtherCAT Trailing Cable * CAT5PLUS * 22AWG (SHIELDED) (UL) E119100 CMX 75°C VERIFIED (UL) CAT 5E PATCH CABLE FRNC *"length in meters"
Printing colour black
Environmental data  
Operation temperature range, moved -40…+70 °C, -40…+158 °F
Operation temperature range, fixed installation -20…+60 °C, -4…+140 °F
UV resistance yes
Oil resistance according to DIN EN 60811-404 (7x24 h/90 °C)
Acid, lye and solvent resistance depends on medium, concentration, temperature and duration
LABS-free yes
Flame-retardant yes
CFC-free yes
Halogen-free yes
Silicone-free yes
Approvals UL-Style AWM 20963
Attenuation  
Max. insertion loss
Frequency [MHz] 1 4 10 16 20 31.25 62.5 100
[db/100 m] 2.1 4.0 6.3 8.0 9.0 11.4 16.5 21.3
[db/100 ft] 0.6 1.2 1.9 2.4 2.7 3.5 5 6.5
Min. near-end crosstalk attenuation
Frequency [MHz] 1 4 10 16 20 31.25 62.5 100
[db/100 m] 80 76.0 70.0 65.0 63.0 60.0 55.0 50.0
[db/100 ft] 24.4 23.2 21.3 19.8 19.2 18.3 16.8 15.2

Notes

- The following length tolerances apply: 2-3 %

- Illustrations similar

Ordering information Length
ZB9024 sold by the metre

Beckhoff®, TwinCAT®, EtherCAT®, EtherCAT P®, Safety over EtherCAT®, TwinSAFE®, XFC® and XTS® are registered trademarks of and licensed by Beckhoff Automation GmbH. Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners.

 

© Beckhoff Automation GmbH & Co. KG 03/2019

 

The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual application do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressively agreed in the terms of contract.