M8, plug, straight, male, 4-pin, A‑coded – open end, 4-wire + shielding
Electrical data | Head A | Head B |
---|---|---|
Rated voltage | 30 V (according to IEC 61076-2-101) | - |
Rated current | 4 A at 40 °C (according to IEC 61076-2-101) | - |
Shielding | yes | - |
Insulation resistance | ≥ 100 GΩ (according to IEC 60512) | - |
Mechanical data | ||
Installation size | M8 | open end |
Connector type | plug | - |
Configuration | straight | - |
Contact type | male | - |
Number of positions (face) | 4-pin | 4-wire + shielding |
Coding | A‑coded | - |
Recommended torque, nut | 0.4 Nm | - |
Mating cycles | ≥ 100 | - |
Way of locking | screw | - |
Weight per piece | 0.028 kg (0.0617 lb) | - |
Body colour | black | - |
Body material | TPU, UL94 | - |
Coupling nut material | GD-Zn, Ni | - |
Seal | FPM | - |
Contact carrier colour | green | - |
Contact carrier material | PA 6, UL 94 V-0 | - |
Contact material | CuZn | - |
Contact plating | Ni, Au gal. | - |
Environmental data | ||
Special features | halogen-free, flame-resistant as per IEC 60332-1-2, oil-resistant as per DIN EN 60811-2-1 | - |
RoHS compliant | yes | - |
Ambient temperature, operation | -30…+70 °C, -22…+158 °F | - |
Protection class | IP 67 in screwed condition (according to IEC 60529) | - |
Pollution level | 3/2 (according to IEC 60664-1) | - |
![]() |
![]() |
![]() |
Electrical data | |
---|---|
Rated voltage | 30 V (according to IEC 61076-2-101) |
Attenuation of shielding | ≥ 43 dB |
Insulation resistance | ≥ 150 MΩ/km |
Unbalanced capacitance to ground | 3400 pF/km |
Mutual capacitance | 51 pF/m at 1 kHz |
Characteristic impedance (Ethernet) | 100 Ω ±15 Ω (100 MHz) |
Loop resistance (Ethernet) | 250 Ω/km |
Unbalanced resistance (Ethernet) | 2 % |
Dielectric strength wire/wire (Ethernet) | 1000 V DC/700 V AC |
Dielectric strength wire/shield (Ethernet) | 1000 V DC/700 V AC |
Signal running time (Ethernet) | 5.55 ns/m |
Electrical parameters (Ethernet) | based on CAT 5 |
Test voltage | 700 V |
Mechanical data | |
Cable structure (Ethernet) | star quad |
Conductor construction (Ethernet) | 19 x 0.1 mm |
Cross section (Ethernet) | 0.14 mm² (AWG26) |
Min. bending radius, moved | 20 x outer cable diameter |
Min. bending radius, fixed installation | 4 x outer cable diameter |
Weight | 40 kg/km (26.9 lb/1000 ft) |
Outer cable diameter | 5.4 mm ± 0.3 mm (0.213" ±0.0118") |
Conductor material (Ethernet) | copper, tinned |
Optical covering factor of shielding (Ethernet) | 90 % |
Use | drag-chain suitable |
Max. acceleration | 10 m/s² |
Max. speed | 15 m/s |
Max. number of cycles | 20 million (5 million with 14 x D, v = 5 m/s and a = 15 m/s²) |
Wall thickness of wire insulation (Ethernet) | 0.25 mm |
Jacket colour | green |
Material jacket | PUR (polyurethane) |
Wire colour code | yellow, orange, white, blue |
Wire insulation material | PP (polypropylene) |
Printing on the jacket | "sequential length in meters" Industrial Ethernet Cat5 trailing * E130266 “UL Recognized” UL AWM 20963 80 °C 30V * ZB9032 “month/year” “ internal order number” |
Printing colour | black |
Environmental data | |
Operation temperature range, moved | -40…+80 °C, -40…+176 °F |
Oil resistance | according to DIN EN 60811-404 (7x24 h/90 °C) |
Acid, lye and solvent resistance | depends on medium, concentration, temperature and duration |
Approvals | UL-Style AWM 20963 |
![]() |
![]() |
Attenuation | ||||||||
---|---|---|---|---|---|---|---|---|
Max. insertion loss | ||||||||
Frequency [MHz] | 1 | 4 | 10 | 16 | 20 | 31.25 | 62.5 | 100 |
[db/100 m] | 3.1 | 6.5 | 9.9 | 12.3 | 13.8 | 17.7 | 25.6 | 33.0 |
[db/100 ft] | 0.9 | 2 | 3 | 3.7 | 4.2 | 5.4 | 7.8 | 10.1 |
Min. near-end crosstalk attenuation | ||||||||
Frequency [MHz] | 1 | 4 | 10 | 16 | 20 | 31.25 | 62.5 | 100 |
[db/100 m] | 62 | 53.0 | 47.0 | 44.0 | 42.0 | 40.0 | 35.0 | 32.0 |
[db/100 ft] | 18.9 | 16.2 | 14.3 | 13.4 | 12.8 | 12.2 | 10.7 | 9.8 |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Contact assembly | |
---|---|
![]() |
|
![]() |
![]() |
Dimensions | |
---|---|
![]() ![]() |
|
A1 | 41.00 mm |
![]() |
![]() |
- Depending on the cable length (L), the following length tolerances apply:
0 m…<0.2 m: ± 10 mm | 0.2…4.0 m: + 40 mm | ≥ 4.0 m: + 1 %
- Illustrations similar
- Further cable length on request. The last three digits of the ordering information is the cable length in decimeters, e.g.ZKxxxx-xxxx-x020 = cable length 2.00 m
Ordering information | Length |
---|---|
ZK1090-3100-0005 | 0.50 m |
ZK1090-3100-0010 | 1.00 m |
ZK1090-3100-0020 | 2.00 m |
ZK1090-3100-0030 | 3.00 m |
ZK1090-3100-0050 | 5.00 m |
ZK1090-3100-0070 | 7.00 m |
ZK1090-3100-0080 | 8.00 m |
ZK1090-3100-0100 | 10.00 m |
ZK1090-3100-0150 | 15.00 m |
ZK1090-3100-0300 | 30.00 m |
ZK1090-3100-0400 | 40.00 m |
ZK1090-3100-0500 | 50.00 m |
![]() |
![]() |
Beckhoff®, TwinCAT®, EtherCAT®, EtherCAT P®, Safety over EtherCAT®, TwinSAFE®, XFC® and XTS® are registered trademarks of and licensed by Beckhoff Automation GmbH. Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners.
© Beckhoff Automation GmbH & Co. KG 09/2018
The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual application do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressively agreed in the terms of contract. |