EL3314-0020 | 4-channel thermocouple input terminal, high-precision, with open-circuit recognition, with calibration certificate

EL3314-0020 | 4-channel thermocouple input terminal, high-precision, with open-circuit recognition, with calibration certificate

EL3314-0020 | 4-channel thermocouple input terminal, high-precision, with open-circuit recognition, with calibration certificate

Run LED
Run LED
Run LED
Run LED
Error LED 1
Error LED 2
Error LED 3
Error LED 4
+TC1
+TC2
+TC3
+TC4
-TC1
-TC2
-TC3
-TC4
Top view 
Contact assembly 
Observe for earthed
thermocoupler:
differential inputs
max. ± 2 V to ground
EL3314-0020 | 4-channel thermocouple input terminal, high-precision, with open-circuit recognition, with calibration certificate

EL3314-0020 | 4-channel thermocouple input terminal, high-precision, with open-circuit recognition, with calibration certificate

For demanding applications: calibrated analog inputs

Thermocouple measurement with Beckhoff components: precise and fast

Measurement technology easily configured: Analog EtherCAT input terminals.

Measurement technology simply integrated: With the analog EtherCAT Terminals.

For demanding applications: calibrated analog inputs

Thermocouple measurement with Beckhoff components: precise and fast

Measurement technology easily configured: Analog EtherCAT input terminals.

Measurement technology simply integrated: With the analog EtherCAT Terminals.

The EL3314-0020 analog input terminal allows four thermocouples to be connected directly. The EtherCAT Terminal circuit can operate thermocouple sensors using the 2-wire technique. A microprocessor handles linearisation across the whole temperature range, which is freely selectable. The error LEDs indicate a broken wire. Compensation for the cold junction is made through an internal high-precision temperature measurement at the terminal. The EL3314-0020 can also be used for mV measurement.

The desired calibration certificate can be downloaded from here using the respective serial number.

 

Product status:

Product announcement | estimated market release on request

Product information