

The EL6720 Lightbus master terminal enables the connection to Lightbus devices just as the Beckhoff FC2001 Lightbus PCI card. Due to the connection via EtherCAT, no PCI slots are required in the PC. The terminal controls the Lightbus protocol with all its features. Within an EtherCAT Terminal network, the EL6720 enables the integration of any Lightbus slaves. The terminal has a powerful protocol implementation with many features:
| Technical data | EL6720 |
|---|---|
| Fieldbus | Lightbus |
| Number of fieldbus channels | 1 |
| Function | master |
| Data transfer rates | 2.5 Mbaud |
| Bus interface | 2 x standard fibre optic connector Z1000 (plastic fibre), Z1010 (HCS fibre) |
| Communication | 3 priority controlled logical communication channels |
| Bus device | max. 254 nodes with a max. of 65,280 I/O points per fieldbus connection |
| Hardware diagnosis | 3 LEDs |
| Current consumption E-bus | typ. 240 mA |
| Weight | approx. 70 g |
| Operating/storage temperature | 0…+55 °C/-25…+85 °C |
| Relative humidity | 95 %, no condensation |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27/29 |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. class/installation pos. | IP 20/variable |
Product announcement |
estimated market release 1st quarter 2009 |