Building automation Room Controller BC9191
Ethernet RJ 45
(switched)
Ethernet RJ 45
(switched)
Connection
to KL6583
(EnOcean)
3 Digital
inputs
1 LED
Digital
output
Analog inputs:
3 x 0…10 V
Analog input:
1 x resistance
measurement
Analog input:
1 x Ni/PT1000 -
(-20…+60 °C)
Analog outputs:
2 x 0…10 V
Triac outputs:
2 x 230 V AC, 1 A
Relay ouputs:
3 x 230 V AC, 1 A
Relay output:
1 x 230 V AC, 10 A
K-bus interface
Power supply

BC9191 | Building automation Room Controller

The BC9191 Room Controller covers the standard functions for the individual room control in a compact design. There are two switched Ethernet interfaces in addition to the necessary I/O signals. A sub-bus is provided for the efficient connection of room control units. The K-bus interface makes extension by the entire range of Bus Terminals possible at any time. The likewise integrated Bus Terminal Controller provides the local intelligence required in order to control the room.

PLC data Ethernet TCP/IP | BC9191
Programming with TwinCAT via Ethernet
Program memory 48 kbytes
Data memory 32 kbytes
Remanent data 2 kbytes
Runtime system 1 PLC task
Programming languages IEC 61131-3 (IL, LD, FBD, SFC, ST)
Online change yes
Technical data BC9191
Number of Bus Terminals 64
Max. number of bytes fieldbus 512 byte input and 512 byte output
Ethernet interface 2 x RJ45 (switched)
Protocol TwinCAT ADS, Modbus TCP
Digital inputs 3 contacts (e.g. window contact, dew point, occupancy sensor)
Analog inputs 3 x 0…10 V (e.g. CO2 sensor, air quality sensor, brightness sensor)
1 x PT/Ni1000 (-20…+60 °C) for air temperature measurement
1 x resistance measurement for set value specification (0…10 KΩ)
Digital outputs 1 x 230 V AC, 10 A, relay (e.g. air heater)
3 x 230 V AC, 1 A, relay (3-stage fan)
2 x 230 V AC, 1 A, triac (e.g. valves for heating and cooling)
Analog outputs 2 x 0…10 V (e.g. volumetric air flow controller)
Bus interface 2 x RJ45 (switched)
Sub bus system Connection to KL6583 (EnOcean)
Supply voltage 230 V AC
Current supply K-bus 200 mA
Dimensions (W x H x D) 118 mm (127 mm with end cover and DIN rail mounting) x 100 mm x 70 mm
Weight approx. 345 g
Operating/storage temperature 0…+55 °C/-25…+85 °C
Protect. class/installation pos. IP 20/vertical
Approvals/markings CE
Accessories/related products  
KS2000 configuration software for extended parameterisation
TX1200 programming system conforms to IEC 61131-3
Cordsets cordsets and connectors
FC9001-0010 | FC9011 Ethernet PCI fieldbus cards
KL6583 EnOcean transmitter and receiver
BC9191-0100 Bus Terminal Controller for Ethernet TCP/IP system, IEC 61131-3, Room Controller, RS485 interface
System  