The EQ3204 EtherCAT Box with analog inputs allows resistance sensors to be connected directly. The module’s circuitry can operate the sensors using 2-, 3- or 4-wire connection techniques. Linearization over the full temperature range is realized with the aid of a microprocessor. The temperature range can be selected freely. The module can also be used for simple resistance measurement with the output in ohms. The module’s standard settings are: resolution 0.1°C in the temperature range of Pt100 sensors in 2-wire connection. Sensor malfunctions such as broken wires are indicated by error LEDs. The module is quite versatile, but the default values are selected in such a way that in most cases it is not necessary to perform configuration. The input filter and associated conversion times can be set within a wide range; several data output formats may be chosen. If required, the inputs can be scaled differently. Automatic limit monitoring is also available. Parameterization is carried out via EtherCAT.
The modules of the EQxxxx series are made of stainless steel in hygienic design. Therefore they are ideal for applications in the food, chemical or pharmaceutical industries, which require protection rating IP69K.
Product status:
regular delivery
Product information
Technical data | EQ3204-0002 |
---|---|
Protocol | EtherCAT |
Bus interface | 2 x M8 socket, 4-pin, a-coded, shielded |
Number of inputs | 4 |
Input connections | M12 x 1, 5-pin, a-coded |
Connection method | M12 socket for 2-, 3- and 4-wire connections, presetting: 2-wire |
Conversion time | 800 ms up to 2 ms, see documentation, default: approx. 85 ms |
Resolution | 0.1°C per digit |
Sensor types | Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, resistance measurement (e.g. potentiometer, 10 Ω…1.2/4 kΩ) |
Signal type | Pt100 |
Measuring range | -200…+850°C (Pt sensors); -60…+250°C (Ni sensors) |
Measurement error/uncertainty | < ±0.5°C (Pt sensors in 4-wire connection) |
Nominal voltage | 24 V DC (-15%/+20%) |
Distributed clocks | – |
Measuring current | typ. 0.5 mA |
Input filter | 5 variations, configurable |
Current consumption from US | 120 mA |
Power supply connection | feed: 1 x M8 male socket, 4-pin, a-coded; downstream connection: 1 x M8 female socket, 4-pin, a-coded |
Electrical isolation | 500 V |
Special features | stainless steel, Hygienic Design |
Operating/storage temperature | -25…+60°C/-40…+85°C |
Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
Protect. rating/installation pos. | IP69K (according to EN 60529)/variable |
Approvals/markings | CE, UL |
Housing data | 4 x M12 |
---|---|
Dimensions (W x H x D) | 39 mm x 160 mm x 43 mm |
Material | stainless steel |
Installation | 2 fixing lugs for M5 |