The EP9224-0037 allows the distribution of one B17 ENP input to four EtherCAT P ports with B17-ENP forwarding. In each EtherCAT P branch, the current consumption for control voltage US and peripheral voltage UP is monitored, limited and, if necessary, switched off.
The input voltage and current values of all outputs can be evaluated via the process data. The power supply and communication of the box runs via a 5-pin B17-ENP connector with up to 14 A (for each US/UP). Several modules can be configured in a cascade arrangement. This voltage is switched off in the case of a short circuit on one of the four outputs or eight voltages (4 x US/UP each). The supply for the other junctions remains active. The switch-off or control takes place in such a way that the input voltage does not fall below a critical value. In the event of an error, continuous data logging of the relevant data can be retrieved. During startup consumers with large capacities can be added without problem.
Diagnostic messages of the individual channels can be read by the master via the EtherCAT interface.
Advantages:
- 4 independent EtherCAT P segments
- Switch-off characteristic can be selected for each channel.
- Channels can be switched on and off individually.
- current and voltage values as process data
- diagnostic data logging
Independent switching of individual consumer branches is also possible via the EtherCAT master.
Product status:
regular delivery
Product information
Technical data | EP9224-0037 |
---|---|
Protocol | EtherCAT |
Bus interface | 2 x B17 ENP, bayonet fitting, shielded |
Task within EtherCAT system | coupling to the EtherCAT network, EtherCAT P junction, feed in and monitoring of US and UP |
Number of channels | IN: 1 x ENP, OUT: 1 x ENP, 4 x EtherCAT P |
Infeed | ENP B17 5-pin, max. 15.5 A per US/UP at 45 °C |
Power feedthrough | ENP B17 5-pin, max. 15.5 A per US/UP at 45 °C |
Current rating per port | max. 3 A per US and UP (M8 P-coded) |
Data logging | recording of relevant data in case of failure |
Special features | input voltages/currents, output currents via process data |
Operating/storage temperature | -25…+60°C/-40…+85°C |
Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
Approvals/markings | CE, UL (in preparation) |
Housing data | B17 infeed |
---|---|
Dimensions (W x H x D) | 60 mm x 150 mm x 26.5 mm |
Material | PA6 (polyamide) |
Installation | 2 fixing holes 3.5 mm diameter for M3; 2 fixing holes 4.5 mm diameter for M4 |