The ED2504 EtherCAT Terminal offers up to four digital outputs, which are output as pulse-width modulated signals. The output signal can be modulated in both pulse width and frequency in the range of 1 Hz to 64 kHz. The output level is determined by the external voltage fed in and can be freely selected in the range from 5 V DC to 24 V DC.
The outputs are short circuit and overcurrent protected. Each channel also has a digital input with configurable filter times. The switching characteristic can be selected as either positive or ground switching (PNP/NPN) for each channel.
The input can be used as a digital input or to enable the PWM output. If the PWM signal is used to control the fan, for example, the additional input can be used for the measurement of rotary speed.
The ED series EtherCAT Terminals have push-in connection technology which makes wiring easy and tool-free.
Product status:
regular delivery
Product information
| General | ED2504 |
|---|---|
| Number of channels | Total | max. 8 |
| Internal communication protocol | EtherCAT |
| Digital output | ED2504 |
|---|---|
| PWM | |
| Number of channels | 4 |
| Load type | resistive, inductive |
| Signal range | Technical | 5…24 V DC (+20%) (external supply) |
| Output current | max. 1.5 A per channel* |
| Short-circuit proof | yes |
| Output stage | push-pull |
| Pulse duration | TON | typ. > 320 ns |
| Pulse duration | TOFF | typ. > 320 ns |
| Duty cycle | 0…100% |
| Resolution | 10...16 bit |
| Output frequency | 1 Hz…64 kHz |
| Reverse polarity protection | yes |
*for operational information, see documentation
| Digital input | ED2504 |
|---|---|
| Standard digital | Positive switching | |
| Number of channels | max. 4 |
| Function | digital input, hardware gate, tachometer |
| Connection technology | 1-wire |
| Signal voltage “0” | -3…+1.5 V DC |
| Signal voltage “1” | 2.7…28 V DC |
| Input filter | typ. 1 µs, 0.1 ms, 0.5 ms, 1 ms, 3 ms, 10 ms, 20 ms (adjustable) |
| Input current | typ. 1 mA at 24 V DC |
| Cable length | Sensor cable | max. 30 m |
| Standard digital | Ground switching | |
| Number of channels | max. 4 |
| Function | digital input, hardware gate, tachometer |
| Connection technology | 1-wire |
| Signal voltage “0” | 2.5…28 V DC |
| Signal voltage “1” | -3…+1 V DC |
| Input filter | typ. 1 µs, 0.1 ms, 0.5 ms, 1 ms, 3 ms, 10 ms, 20 ms (adjustable) |
| Input current | typ. 2 mA at 24 V DC |
| Cable length | Sensor cable | max. 30 m |
| XFC | ED2504 |
|---|---|
| Distributed clocks | no |
| Timestamp | no |
| Oversampling | no |
| Supply and electrical isolation | ED2504 |
|---|---|
| Electronics | Supply voltage | via E-bus, via power contacts |
| E-bus | Current consumption | typ. 100 mA |
| Power contacts | Input voltage | 24 V DC (-15%/+20%) |
| Power contacts | Current carrying capacity | max. 10 A |
| Power contacts | Current consumption | typ. 5 mA + load |
| Power contacts | Output voltage | corresponds to Power contacts | Input voltage |
| Electrical isolation | Channel/channel | no |
| Electrical isolation | Channel/bus | functional, 707 V DC type test |
| Environmental conditions | ED2504 |
|---|---|
| Operating temperature | -25…+60°C |
| Storage temperature | -40…+85°C |
| Relative humidity | 95%, no condensation |
| Installation position | variable |
| Standards and approvals | ED2504 |
|---|---|
| Vibration resistance | conforms to EN 60068-2-6 |
| Shock resistance | conforms to EN 60068-2-27 |
| EMC immunity | conforms to EN 61000-6-2 |
| EMC emission | conforms to EN 61000-6-4 |
| Markings | CE |
| Approvals | UL |
| Housing data | ED-12-16pin |
|---|---|
| Weight | approx. 60 g |
| Protection rating | IP20 |
| Material | polycarbonate |
| Dimensions | Width (single) | 15 mm |
| Dimensions | Width (stacked) | 12 mm |
| Dimensions | Height | 100 mm |
| Dimensions | Depth | 65 mm |
| Installation | Terminal/back wall | DIN rail, 35 mm (EN 60715) |
| Installation | Terminal/terminal | double slot and key connection |
| Pluggable wiring level | no |
| Connection mechanism | push-in |
| Connection cross-section | Solid wire | 0.08…1.5 mm² |
| Connection cross-section | Stranded wire | 0.25…1.5 mm² |
| Connection cross-section | With ferrule | 0.14…0.75 mm² |
| Connection cross-section AWG | Solid wire | AWG28…16 |
| Connection cross-section AWG | Stranded wire | AWG22…16 |
| Connection cross-section AWG | With ferrule | AWG26…19 |
| Stripping length | 8…9 mm |
| Power contact | "+" (left) | yes |
| Power contact | "+" (right) | yes |
| Power contact | "-" (left) | yes |
| Power contact | "-" (right) | yes |
| Power contact | "⏚" (left) | no |
| Power contact | "⏚" (right) | no |
| Insertion lock for power contact "⏚" | yes |
Loading content ...
| Material compliance | ED2504 |
|---|---|
| CAS No. | 7439-92-1 |
| REACH SVHC | Lead |
| REACH Annex XVII | compliant |
| REACH Annex XIV | compliant |
| POP | compliant |
| RoHS | compliant with exemption |
| RoHS exemption | 7a: Lead in solders with a high melting point with a minimum mass fraction of 85% lead, 7c-I: Lead-containing electrical and electronic components in glass and ceramic materials, excluding dielectric ceramics in capacitors |
| China-RoHS | www.beckhoff.com/china-rohs-io |
| CA Prop65 | www.beckhoff.com/prop65 |
| Disclaimer | This statement and the information contained above are, to the best of our knowledge and belief, accurate, based on the information we have received from our suppliers. This information is in line with the current standard of technology and our suppliers’ technical documentation. The absence of the substances is not verified by Beckhoff Automation by means of analytical tests. When addressed to our customers any information contained in this document is subject to the terms and conditions expressed in the governing customer agreement. Our general terms and conditions apply. |
Loading content ...
Loading content ...
Loading content ...
Loading content ...
© Beckhoff Automation 2026 - Terms of Use