Ordering instructions for special couplers and terminals
All Bus Couplers and Bus Terminals are supplied with a standard configuration. In addition, specific coupler and terminal types with modified software or hardware are available. These variants have an order number with additional four figures. Therefore, if you do require a configuration other than standard, quote this extended number when you place your order. The following table provides a summary of the Bus Couplers and Bus Terminals that are available.
Bus Coupler | Feature | ||||
---|---|---|---|---|---|
BK8100-0060 | watchdog special setting 60 s | ||||
BK8100-1001 | watchdog special setting 10 s | ||||
BK9055-1000 | EtherNet/IP Compact Bus Coupler for up to 64 Bus Terminals (255 with K-bus extension), default IP address: 192.168.1.xxx | ||||
BK9105-1000 | EtherNet/IP Bus Coupler for up to 64 Bus Terminals (255 with K-bus extension), default IP address: 192.168.1.xxx | ||||
Digital input | Feature | ||||
KL1052-0010 | 2-channel digital input terminal 96 V DC positive/ground switching, not in accordance with the EN 61131-2 specifications: I high = 3 mA, I low = 0.5 mA | ||||
KL1232-0001 | positive switching, positive edge-triggered input, 10 ms pulse extension, input filter 0.2 ms | ||||
KL1232-0002 | positive switching, positive edge-triggered input, 20 ms pulse extension, input filter 0.2 ms | ||||
KL1232-0010 | positive switching, positive edge-triggered input, 100 ms pulse extension, input filter 3.0 ms | ||||
KL1232-0100 | positive switching, negative edge-triggered input, 100 ms pulse extension, input filter 0.2 ms | ||||
KL1232-0110 | positive switching, negative edge-triggered input, 100 ms pulse extension, input filter 3.0 ms | ||||
KL1232-1000 | ground switching, positive edge-triggered input, 100 ms pulse extension, input filter 0.2 ms | ||||
KL1232-1001 | 5 V, ground switching, negative edge-triggered input, 20 ms pulse extension, input filter 0.2 ms | ||||
KL1232-1010 | ground switching, positive edge-triggered input, 100 ms pulse extension, input filter 3.0 ms | ||||
KL1232-1100 | ground switching, negative edge-triggered input, 100 ms pulse extension, input filter 0.2 ms | ||||
KL1232-1110 | ground switching, negative edge-triggered input, 100 ms pulse extension, input filter 3.0 ms | ||||
KL1232-2000 | positive switching, positive edge-triggered input, 200 ms pulse extension, input filter 0.2 ms | ||||
KL1501-0010 | gate-counter with auto-reset and setting A0 | ||||
KL1501-0011 | up/down counter with 5 V inputs, 24 V DC outputs | ||||
KL1702-0010 | 230 V AC input circuit with type 2 characteristics | ||||
KL1712-0010 | 24 V AC/DC input circuit | ||||
Digital output | Feature | ||||
KL2502-3020 | 5 V output, 30 kHz limit frequency | ||||
KL2521-0010 | with additional outputs (230 V AC/DC, 100 mA) instead of the additional inputs of the default variant | ||||
KL2521-0024 | for 24 V signal level | ||||
KL2541-0006 | stepper motor terminal 50 V DC, 5 A, 5 V DC encoder operating voltage | ||||
KL2702-0002 | 2-channel solid state load relay up to 230 V AC/DC, 2 A, mutually locked (no UL, GL or Ex approval) | ||||
KL2702-0020 | 2-channel solid state load relay up to 230 V AC/DC, 1.5 A (no UL, GL or Ex approval) | ||||
KL2722-0010 | without reciprocal locking of the channels, total current 1 A | ||||
KL2732-0010 | without reciprocal locking of the channels, total current 1 A | ||||
KL2751-0011 | dimmer terminal without power contacts | ||||
KL2761-0011 | 1-channel universal dimmer terminal, 230 V AC, 600 VA (W), 50 Hz, without power contacts | ||||
KL2791-0011 | 1-channel AC motor speed controller, 230 V AC, 200 VA, max. 0.9 A, without power contacts | ||||
Analog input | Feature | ||||
KL3002-0010 | Siemens S5 format | ||||
KL3002-0011 | fast µP, scan time approx. 0.5 ms | ||||
KL3002-0050 | Siemens S7 format | ||||
KL3012-0010 | Siemens S5 format | ||||
KL3012-0011 | altered range: 0…21.5 mA, maximum value corresponds to 21.5 mA instead of 20 mA | ||||
KL3012-0012 | fast µP, scan time approx. 0.5 ms | ||||
KL3012-0050 | Siemens S7 format | ||||
KL3022-0010 | Siemens S5 format | ||||
KL3022-0011 | fast µP, scan time approx. 0.5 ms | ||||
KL3022-0050 | Siemens S7 format | ||||
KL3042-0010 | Siemens S5 format | ||||
KL3042-0011 | fast µP, scan time approx. 0.5 ms | ||||
KL3042-0012 | altered range: 0…21.5 mA, maximum value corresponds to 21.5 mA instead of 20 mA | ||||
KL3042-0050 | Siemens S7 format | ||||
KL3044-0050 | Siemens S7 format | ||||
KL3051-0050 | Siemens S7 format | ||||
KL3052-0010 | Siemens S5 format | ||||
KL3052-0011 | fast µP, scan time approx. 0.5 ms | ||||
KL3052-0012 | changed diagnostic level (< 3.5 mA or > 21.5 mA) | ||||
KL3052-0050 | Siemens S7 format | ||||
KL3054-0050 | Siemens S7 format | ||||
KL3062-0010 | Siemens S5 format | ||||
KL3062-0011 | voltage level 0…20 V | ||||
KL3062-0012 | fast µP, scan time approx. 0.5 ms | ||||
KL3062-0013 | voltage level 0…30 V | ||||
KL3062-0014 | voltage level 0…50 V | ||||
KL3062-0050 | Siemens S7 format | ||||
KL3064-0010 | Siemens S5 format | ||||
KL3064-0011 | voltage level 0…20 V | ||||
KL3064-0050 | Siemens S7 format | ||||
KL3102-0050 | Siemens S7 format | ||||
KL3112-0050 | Siemens S7 format | ||||
KL3122-0050 | Siemens S7 format | ||||
KL3142-0050 | Siemens S7 format | ||||
KL3172-0500 | 2-channel analog input terminal, 0…500 mV | ||||
KL3202-0010 | Pt200 | ||||
KL3202-0011 | Pt200 in Siemens S5 format | ||||
KL3202-0012 | Pt500 | ||||
KL3202-0013 | Pt500 in Siemens S5 format | ||||
KL3202-0014 | Pt1000 | ||||
KL3202-0015 | Pt1000 in Siemens S5 format | ||||
KL3202-0016 | Ni100 | ||||
KL3202-0017 | Ni100 in Siemens S5 format | ||||
KL3202-0020 | resistance measurement 0…1.2 kΩ | ||||
KL3202-0021 | Pt100 in Siemens S5 format | ||||
KL3202-0023 | Ni120 | ||||
KL3202-0024 | Ni120 in Siemens S5 format | ||||
KL3202-0025 | Ni1000 | ||||
KL3202-0026 | Ni1000 in Siemens S5 format | ||||
KL3202-0027 | resistance measurement 10…10 kΩ | ||||
KL3202-0028 | Resolution increased to 0.01 °C; the measurement range is reduced to -40 °C to +128 °C. The absolute accuracy is 0.3 °C, differential error is 0.1 °C. | ||||
KL3202-0029 | Ni1000 per Landis&Staefa characteristic curve (Siemens, 100° corresponds to 1500 Ω) | ||||
KL3204-0014 | Pt1000 | ||||
KL3204-0021 | Pt100 in Siemens S5 format | ||||
KL3204-0025 | Ni1000, 4-channel | ||||
KL3204-0029 | Ni1000 per Landis&Staefa characteristic curve (Siemens, 100° corresponds to 1500 Ω) | ||||
KL3312-0010 | Typ J | ||||
KL3312-0011 | Typ J in Siemens S5 format | ||||
KL3312-0012 | Typ L | ||||
KL3312-0013 | Typ L in Siemens S5 format | ||||
KL3312-0014 | Typ B | ||||
KL3312-0015 | Typ B in Siemens S5 format | ||||
KL3312-0016 | Typ E | ||||
KL3312-0017 | Typ E in Siemens S5 format | ||||
KL3312-0018 | Typ N | ||||
KL3312-0019 | Typ N in Siemens S5 format | ||||
KL3312-0020 | Typ R | ||||
KL3312-0021 | Typ R in Siemens S5 format | ||||
KL3312-0022 | Typ S | ||||
KL3312-0023 | Typ S in Siemens S5 format | ||||
KL3312-0024 | Typ T | ||||
KL3312-0025 | Typ T in Siemens S5 format | ||||
KL3312-0026 | Typ U | ||||
KL3312-0027 | Typ U in Siemens S5 format | ||||
KL3312-0028 | 0…120 mV measurement | ||||
KL3312-0029 | type K in Siemens S5 format | ||||
KL3312-0040 | expanded temperature range for type S and L type S: -50…+1700 °C (as supplied type L: -100…+900 °C) | ||||
KL3312-0110 | type J, Fahrenheit scaling | ||||
KL3312-2000 | setting of reference junction temperature via process image, unit 1/256 °C in a 16 bit word | ||||
KL3312-2100 | external reference point temperature specification via process image is possible, the unit is 1/256 °C in 16-bit format, fast conversion time 65 ms | ||||
KL3351-0001 | 1-channel resistor bridge terminal (strain gauge), with faster measurement time approx. 10 ms | ||||
KL3403-0010 |
3-phase power measurement terminal, current path designed for 5 A transducer (1 % measuring accuracy I), operating/storage temperature: -25…+60 °C/-40…+85 °C |
||||
KL3403-0020 |
3-phase power measurement terminal, current path designed for 20 mA, optimized for electronic current transformer, operating/storage temperature: 0…+55 °C/-25…+85 °C |
||||
KL3403-0022 |
3-phase power measurement terminal, current path and voltage input designed for 20 mA, operating/storage temperature: 0…+55 °C/-25…+85 °C |
||||
KL3403-0333 |
3-phase power measurement terminal, 500 V AC, 333 mV AC, operating/storage temperature: 0…+55 °C/-25…+85 °C |
||||
KL3454-0050 | Siemens S7 format | ||||
KM3701-0340 | differential pressure up to 340 hPa | ||||
Analog output | Feature | ||||
KL4002-0010 | Siemens S5 format | ||||
KL4002-0011 | fast µP, scan time approx. 0.15 ms | ||||
KL4002-0050 | Siemens S7 format | ||||
KL4004-0050 | Siemens S7 format | ||||
KL4012-0010 | Siemens S5 format | ||||
KL4012-0011 | altered range: 0…21.5 mA, maximum value corresponds to 21.5 mA instead of 20 mA | ||||
KL4012-0050 | Siemens S7 format | ||||
KL4021-0050 | Siemens S7 format | ||||
KL4022-0010 | Siemens S5 format | ||||
KL4022-0050 | Siemens S7 format | ||||
KL4032-0010 | Siemens S5 format | ||||
KL4032-0011 | fast µP, scan time approx. 0.15 ms | ||||
KL4032-0050 | Siemens S7 format | ||||
KL4034-0010 | Siemens S5 format | ||||
KL4112-0010 | Siemens S5 format | ||||
KL4112-0050 | Siemens S7 format | ||||
KL4132-0010 | Siemens S5 format | ||||
KL4132-0050 | Siemens S7 format | ||||
KL4428-0050 | Siemens S7 format | ||||
Position measurement | Feature | ||||
KL5111-0010 | A, B, C signals: 5 V inputs | ||||
KL5111-0011 | special function: latch input sets counter to zero | ||||
KL5111-0012 | latches on both edges, A, B, C inputs 24 V | ||||
KL5111-0013 | latches on both edges, A, B, C inputs 5 V | ||||
KL5111-0015 | frequency measurement over a selectable time window; 24 V inputs | ||||
KL5111-0016 | frequency measurement over a selectable time window; 5 V inputs | ||||
KL5111-0020 | 12 V input circuit | ||||
KL5151-0021 | incremental encoder 1 x 32 bit A, B, capture input and 1 driver output 24 V, 0.5 A | ||||
KL5151-0050 | incremental encoder 2 x 32 bit A, B-track | ||||
Communication | Feature | ||||
KL6001-0020 | standard format 5 bytes of user data | ||||
KL6011-0020 | standard format 5 bytes of user data | ||||
KL6021-0020 | standard format 5 bytes of user data (rest default) | ||||
KL6021-0021 | standard format 5 bytes of user data (7 bits, even, 1 stop bit, 9600 baud) | ||||
KL6201-0010 | preset to 22 bytes K-bus interface, supports up to 31 AS-Interface slaves (2 K-bus cycles) | ||||
KL6201-0011 | preset to 38 bytes K-bus interface, supports up to 62 AS-Interface slaves (4 K-bus cycles) | ||||
KL6211-0011 | preset to 38 bytes K-bus interface, supports up to 62 AS-Interface slaves (4 K-bus cycles) | ||||
KL6904-0001 | TwinSAFE Logic Bus Terminal, pre-configured ex factory to 15 TwinSAFE connections | ||||
System | Feature | ||||
KL9210-0020 | with 2 A fuse (slow-blow) and modified label | ||||
KL9540-0010 | surge filter field supply for analog terminals |