KL6201 | Bus Terminal, 1-channel communication interface, ASi, master, without power contacts

KL6201 | Bus Terminal, 1-channel communication interface, ASi, master, without power contacts

KL6201 | Bus Terminal, 1-channel communication interface, ASi, master, without power contacts

K-bus diagnostics
AS-Interface diagnostics/mode
Set
AS-Interface power
AS-Interface fault diagnostics
Mode
Mode
AS-Interface+
AS-Interface-
Set
Mode
AS-Interface+
AS-Interface-
Set
Top view 
Contact assembly 
KL6201 | Bus Terminal, 1-channel communication interface, ASi, master, without power contacts

KL6201 | Bus Terminal, 1-channel communication interface, ASi, master, without power contacts

The AS-Interface master terminal is an extended master according to profile M3 and enables the direct connection of AS-Interface slaves. The AS-Interface-compliant interface supports digital and analog slaves, versions 2.0 and 2.1, safety slaves and slaves with Combined Transaction Type 1 (profile S-7.3 and 7.4). Process data exchange, parameterization and the diagnosis are fieldbus-independent. Together with the different Bus Couplers, the KL6201 represents a universal AS-Interface/fieldbus gateway. Together with the BK3120, the PROFIBUS DP V1 services can be used for communication with the KL6201.

Product status:

KL6201: regular delivery
KS6201: product announcement | estimated market release on request

Product information

Technical dataKL6201
TechnologyAS-Interface
Number of channels1
Number of slaves31 for V 2.0, 62 for V 2.1
Specification versionAS-Interface V 2.0, V 2.1
Slave typesdigital and analog
Diagnosticspower failure, slave failure, parameterization fault
AS-Interface address
assignment
via configuration or automatic
Cycle timemax. 5 ms (31 devices)
Connection2 lines via spring force technology
Current consumption K-bustyp. 55 mA (K-bus), typ. 60 mA (AS-Interface)
Current consumption power contacts– (no power contacts)
Electrical isolation500 V (AS-Interface/K-bus)
Power contactsno
Bit width in the process imageselectable: 12 bytes, 22 bytes or 38 bytes, of which 6 bytes parameter interface
Configurationvia fieldbus parameter interface, DP-V1 or Bus Coupler through KS2000
Weightapprox. 55 g
Operating/storage temperature0…+55°C/-25…+85°C
Relative humidity95%, no condensation
Vibration/shock resistanceconforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emissionconforms to EN 61000-6-2/EN 61000-6-4
Protect. rating/installation pos.IP20/variable
Pluggable wiringfor all KSxxxx Bus Terminals
Approvals/markingsCE, UL, ATEX, IECEx
Ex markingATEX:
II 3 G Ex ec IIC T4 Gc
IECEx:
Ex ec IIC T4 Gc
Housing dataKL-12-8pinKS-12-8pin
Design formcompact terminal housing with signal LEDsterminal housing with pluggable wiring level
Materialpolycarbonate
Dimensions (W x H x D)12 mm x 100 mm x 68 mm
Installationon 35 mm DIN rail, conforming to EN 60715 with lock
Side by side mounting by means ofdouble slot and key connection
Markinglabeling of the BZxxx series
Wiringsolid conductor (s), flexible conductor (st) and ferrule (f): spring actuation by screwdriver
Connection cross-sections*: 0.08…2.5 mm²,
st*: 0.08…2.5 mm²,
f*: 0.14…1.5 mm²
s*: 0.08…1.5 mm²,
st*: 0.08…1.5 mm²,
f*: 0.14…1.5 mm²
Connection cross-section AWGs*: AWG28…14,
st*: AWG28…14,
f*: AWG26…16
s*: AWG28…16,
st*: AWG28…16,
f*: AWG26…16
Stripping length8…9 mm9…10 mm
Current load power contactsImax: 10 A

*s: solid wire; st: stranded wire; f: with ferrule

Ordering information
KL6201Bus Terminal, 1-channel communication interface, ASi, master, without power contacts
KS6201Bus Terminal, 1-channel communication interface, ASi, master, without power contacts, pluggable wiring
KL6201-0010Bus Terminal, 1-channel communication interface, ASi, master, without power contacts, preset to 22 bytes K-bus interface, supports up to 31 AS-Interface slaves (2 K-bus cycles)
KL6201-0011Bus Terminal, 1-channel communication interface, ASi, master, without power contacts, preset to 38 bytes K-bus interface, supports up to 62 AS-Interface slaves (4 K-bus cycles)