The EL3174-0030 analog input terminal has four individually parameterizable inputs. Signals in the range from -10/0 to +10 V or -20/0/+4 to +20 mA can be processed via each channel. Physically, the voltage and current signals should be connected to different terminal points. Each channel should then be set by the controller/TwinCAT to U or I mode via CoE. The voltage inputs operate differentially; the current inputs are single-ended. All inputs are digitized with a resolution of 16 bits and transmitted, electrically isolated, to the higher-level automation device. With a technical measuring range of ±107 % of the nominal range, the terminal also supports commissioning with sensor values in the limit range and diagnostics according to NAMUR NE43.
For the EL3174-0030, an individual calibration certificate is available, currently as a choice of DAkkS or IS0 17025-compliant certificate. The certificate is issued by an accredited service provider in collaboration with Beckhoff.
The desired calibration certificate can be downloaded from here using the respective serial number.
Product status:
regular delivery
Product information
Technical data | EL3174-0030 |
---|---|
Number of inputs | 4 |
Power supply | via the E-bus |
Technology | U differential, I single-ended |
Signal type | differential |
Oversampling factor | – |
Distributed clocks | yes |
Distributed clock precision | << 1 µs |
Internal resistance | > 200 kΩ | typ. 85 Ω |
Input filter limit frequency | 5 kHz |
Common-mode voltage UCM | max. 35 V (voltage measurement) |
Dielectric strength | max. 30 V (current measurement) |
Conversion time | minimum 150 µs |
Measuring range, nominal | -10/0…+10 V | -20/0/+4…+20 mA |
Measuring range, technical | -10.73…+10.73 V | -21.47…+21.47 mA |
Resolution | 16 bit (incl. sign) |
Measurement error/ uncertainty | < ±0.3 % (relative to full scale value) |
Calibration certificate (analog) | externally calibrated |
Electrical isolation | 500 V (E-bus/signal voltage) |
Current consumption power contacts | load-dependent |
Current consumption E-bus | typ. 180 mA |
Bit width in the process image | inputs: 16 byte |
Configuration | no address or configuration setting |
Special features | U/I parameterizable, ExtendedRange, standard and compact process image, activatable FIR/IIR filters |
Weight | approx. 65 g |
Operating/storage temperature | 0…+55 °C/-25…+85 °C |
Relative humidity | 95 %, no condensation |
Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
Protect. rating/installation pos. | IP20/variable |
Approvals/markings | CE, UL |
Housing data | EL-12-16pin |
---|---|
Design form | HD (High Density) housing with signal LEDs |
Material | polycarbonate |
Dimensions (W x H x D) | 12 mm x 100 mm x 68 mm |
Installation | on 35 mm DIN rail, conforming to EN 60715 with lock |
Side by side mounting by means of | double slot and key connection |
Marking | labeling of the BZxxx series |
Wiring | solid conductors (s): direct plug-in technique; fine-stranded conductors (st) and ferrule (f): spring actuation by screwdriver |
Connection cross-section | s*: 0.08…1.5 mm², st*: 0.25…1.5 mm², f*: 0.14…0.75 mm² |
Connection cross-section AWG | s*: AWG 28…16, st*: AWG 22…16, f*: AWG 26…19 |
Stripping length | 8…9 mm |
Current load power contacts | Imax: 10 A |
*s: solid wire; st: stranded wire; f: with ferrule
Loading content ...
Loading content ...
Loading content ...
Loading content ...
© Beckhoff Automation 2023 - Terms of Use