DetachFixClose

EP3744-1041 | Pressure measuring box, 6 digital inputs 24 V DC, 2 digital outputs 24 V DC, 0.5 A, 4 pressure inputs 0…7 bar

EP3744-1041 | Pressure measuring box, 6 digital inputs 24 V DC, 2 digital outputs 24 V DC, 0.5 A, 4 pressure inputs 0…7 bar

EP3744-1041 | Pressure measuring box, 6 digital inputs 24 V DC, 2 digital outputs 24 V DC, 0.5 A, 4 pressure inputs 0…7 bar


EtherCAT signal input


EtherCAT signal output


M8 I/O connection sockets


Signal status display


Labelling areas


Pressure measurement,
6-mm fitting

Power supply status display:


Box supply (US)


Auxiliary voltage (UP)


Power supply feed


Power supply downstream
connection

1 | Tx+
2 | Rx+
3 | Rx-
4 | Tx-

1 | +24 V DC US
2 | Input
3 | GND
4 | Input

1 | +24 V DC US
2 | Output
3 | GND
4 | Input

1 | +24 V DC US
2 | +24 V DC UP
3 | GNDS
4 | GNDP

Socket 2 and 3

Socket 0 and 1

Top view 

I/O connection 

Connector assignment 
EP3744-1041 | Pressure measuring box, 6 digital inputs 24 V DC, 2 digital outputs 24 V DC, 0.5 A, 4 pressure inputs 0…7 bar

EP3744-1041 | Pressure measuring box, 6 digital inputs 24 V DC, 2 digital outputs 24 V DC, 0.5 A, 4 pressure inputs 0…7 bar

The EP3744-1041 EtherCAT Box, equipped with six digital inputs, two digital outputs and four pressure inputs, acquires these signals and transmits them – electrically isolated – to the controller. The signal status is indicated by LEDs; the digital signals are connected via 4-pin M8 screw type connectors.

The pressure is measured as the differential pressure to the fifth connection by an integrated 6 mm fitting. The pressure values are available as 16-bit values. Measurement can be made between -7…7 bar, with the value being output in relation to the fifth connection, e.g. for vacuum measurement in relation to the ambient pressure at suction grippers. In absolute-pressure mode it is possible to measure pressures between 0…7 bar.

The operating mode is preselected via CoE parameters. If the supply voltages fall below a certain level (< 18.5 V) a diagnostic bit is set.