EemaldaKinnitaSulge

AX8540-0220-0000 | Combined power supply and axis module

AX8540-0220-0000 | Combined power supply and axis module

AX8540-0220-0000 | Combined power supply and axis module

AX8540-0220-0000 | Combined power supply and axis module

AX8540-0220-0000 | Combined power supply and axis module

Hannover Messe 2019

Hannover Messe 2019

The AX8525 and AX8540 combined power supply and axis modules unite the function of an AX86xx power supply module with an AX81xx axis module in a single device. As a result, the AX-Bridge is not loaded by the axis current of the first axis and up to 50 A DC are available for additional axis modules. The power supply provides 80 A DC to the DC link and contains an internal brake resistor as well as a chopper for the connection of an external brake resistor. The integrated axis module with TwinSAFE safety functions is available with a rated current of 25 A or 40 A and can optionally be ordered with multi-feedback interface.

The TwinCAT 3 Drive Manager 2 serves as commissioning tool. Thanks to the structured design and the wide range of functions, commissioning of the axis is simple and intuitive.

The TwinCAT 3 Safety Editor TE9000 and the TwinSAFE Loader/User TE9200 must be used to implement safety projects.

Product status:

regular delivery

Product variantsNumber of channelsRated output current (channel)Peak output current (channel)TwinSAFE safe drive technologyFeedback systemSupported types of motors
AX8540-0100-0000140 A80 ASTO/SS1OCT, EnDat 3synchronous servomotor | asynchronous motor
AX8540-0120-0000140 A80 ASTO/SS1OCT, EnDat 3, BiSS C, EnDat 2.2/22, TTL (DIFF RS422), SinCos 1 Vppsynchronous servomotor | linear motor | asynchronous motor
AX8540-0200-0000140 A80 ASafe MotionOCT, EnDat 3synchronous servomotor | asynchronous motor
AX8540-0220-0000140 A80 ASafe MotionOCT, EnDat 3, BiSS C, EnDat 2.2/22, TTL (DIFF RS422), SinCos 1 Vppsynchronous servomotor | linear motor | asynchronous motor

Product information

Technical dataAX8540-0220-0000
Functioncombined power supply and axis module with TwinSAFE Logic and multi-feedback interface
Channels1
Rated supply voltage3 x 200…480 V AC
DC link voltagemax. 848 V DC
DC link output current80 A DC
Rated output current (channel)40 A
Peak output current (channel)80 A
FeedbackOCT , EnDat 3 , BiSS C , EnDat 2.2/22 , TTL (DIFF RS422) , SinCos 1 Vpp
System busEtherCAT
Drive profileCiA402 according to IEC 61800-7-201 (CoE)
Realization STOby local TwinSAFE Logic, via FSoE or hard-wired via safe inputs
Safe stop functionsSafe Torque Off (STO), Safe Operating Stop (SOS), Safe Stop 1 (SS1), Safe Stop 2 (SS2)
Safe acceleration functionsSafe Maximum Acceleration (SMA), Safe Acceleration Range (SAR)
Safe braking functionsSafe Brake Control (SBC), Safe Brake Test (SBT)
Safe direction functionsSafe Direction positive (SDIp), Safe Direction negative (SDIn)
Safe speed functionsSafely Limited Speed (SLS), Safe Speed Range (SSR), Safe Speed Monitor (SSM), Safe Maximum Speed (SMS)
Safe position functionsSafely Limited Position (SLP), Safe CAM (SCA), Safely Limited Increment (SLI)
Safety standardEN ISO 13849-1:2015 (Cat 4, PL e), EN 61508:2010 (SIL 3) and EN 62061:2005 + A1:2013/A2:2015 (SIL CL3)
Ambient temperature (operation)0…+40°C, up to +55°C with power reduction (see documentation)
Approvals/markingsCE, cULus, EAC
Housing dataAX85xx-xxxx
Protection ratingIP20
Width360 mm
DimensionsAX8540-0220-0000
Height without connectors230 mm
Depth without connectors192 mm
Width360 mm