The MO2262-0000-1112 digital output module connects the binary control output signals at the process level with electrical isolation. The outputs are controlled with an adjustable integral multiple (oversampling factor: n) of the bus cycle frequency (n microcycles per bus cycle). For each bus cycle, the module receives a process data block that is output consecutively. The timebase of the module can be synchronized precisely with other EtherCAT devices via distributed clocks. An output pattern with a significantly higher pulse sequence than the bus cycle time is thus output precisely with the system-wide timebase. This procedure enables the temporal resolution of the digital output signals to be increased to n times the bus cycle time. The maximum output rate is 1 Msamples/s.
Special features:
- push-pull output
- connection of different load types possible (ohmic, inductive, lamp load)
- synchronized operation through distributed clocks XFC technology possible
- multiple sampling of a process data through oversampling
Product status:
product announcement
Product information
Technical data | MO2262-0000-1112 |
---|---|
Product category | I/O modules |
Category/version | digital output |
Channels | 2 |
Output voltage | 24 V DC (-15 %/+20 %) |
Output current | 0.5 A per channel |
Specification | positive switching |
Connection method | M12 |
Load type | ohmic, inductive, lamp load |
Switching times | typ. TON: < 1 µs, typ. TOFF: < 1 µs |
Supply voltage from backplane | 24 V DC |
Baseplate interface | data connector |
Diagnostics | yes, status and live data via app |
Distributed clocks | yes |
Hot swap | yes |
Oversampling | yes |
TwinCAT version | TwinCAT 3 |
Weight | approx. 250 g |
Approvals/markings | CE, (UL in preparation) |
Housing data | R1S1T1 |
---|---|
Dimensions (W x H x D) | 30 mm × 110 mm × 32 mm |
Number of rows | 1 |
Number of slots | 1 |
Material | zinc die-cast |
Cooling | convection |
Operating/storage temperature | 0…+50 °C/-25…+85 °C |
Protect. rating/installation pos. | IP65/67/variable |
Loading content ...
© Beckhoff Automation 2024 - Terms of Use