The analog EL3356 input terminal enables direct connection of a resistor bridge or load cell in a 4- or 6-wire connection technology. The ratio between the bridge voltage UD and the supply voltage UREF is determined simultaneously in the input circuit and the final load value is calculated as a process value on the basis of the settings in the terminal. With automatic self-calibration (can be deactivated) and dynamic filters the terminal with measuring cycles of 10 ms can be used for slow weighings with high precision.
Product status:
regular delivery
Product information
| Technical data | EL3356 | 
|---|---|
| Number of inputs | 2, for 1 resistor bridge in full bridge technology | 
| Power supply | via the E-bus | 
| Distributed clocks | – | 
| Measuring range UD | max. ±27 mV | 
| Measuring range UREF | max. ±13.8 V | 
| Internal resistance | > 200 kΩ (UREF), > 1 MΩ (UD) | 
| Supported nominal sensitivity | all, parameter resolution: 0.01 µV/V; recommended: 0.5…4 mV/V | 
| Input filter limit frequency | 10 kHz low pass (-3 dB) | 
| Conversion rate | 100…4 samples/s (10…250 ms conversion time) | 
| Power supply UV | up to 12 V DC from power contacts, dependent on sensor | 
| Resolution | 16 bit, 32 bit presentation | 
| Measurement error/uncertainty | < ±0.01% for the calculated load value in relation to the final load value with a 12 V feed and 24 mV bridge voltage (hence nominal strain gauge characteristic value of 2 mV/V), self-calibration active, 50 Hz filter active | 
| Current consumption E-bus | typ. 210 mA | 
| Current consumption power contacts | depends on strain gauge supply, min. 1 mA | 
| Special features | self-calibration, quadruple averager, dynamic filters | 
| Weight | approx. 60 g | 
| Operating temperature | -25…+55°C | 
| Storage temperature | -40…+85°C | 
| Relative humidity | 95%, no condensation | 
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 | 
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 | 
| Pluggable wiring | for all ESxxxx terminals | 
| Protect. rating/installation pos. | IP20/variable | 
| Approvals/markings | CE, CCC, UL, ATEX, IECEx | 
| Ex marking | ATEX: II 3 G Ex ec IIC T4 Gc IECEx: Ex ec IIC T4 Gc  | 
| Housing data | EL-12-8pin | ES-12-8pin | 
|---|---|---|
| Design form | compact terminal housing with signal LEDs | terminal housing with pluggable wiring level | 
| Material | polycarbonate | |
| Installation | on 35 mm DIN rail, conforming to EN 60715 with lock | |
| Side by side mounting by means of | double slot and key connection | |
| Marking | labeling of the BZxxxx series | |
| Wiring | solid conductor (s), flexible conductor (st) and ferrule (f): spring actuation by screwdriver | |
| Connection cross-section | s*: 0.08…2.5 mm²,  st*: 0.08…2.5 mm², f*: 0.14…1.5 mm²  | s*: 0.08…1.5 mm², st*: 0.08…1.5 mm², f*: 0.14…1.5 mm²  | 
| Connection cross-section AWG | s*: AWG28…14,  st*: AWG28…14, f*: AWG26…16  | s*: AWG28…16, st*: AWG28…16, f*: AWG26…16  | 
| Stripping length | 8…9 mm | 9…10 mm | 
| Current load power contacts | Imax: 10 A | |
| Dimensions (W x H x D) | 12 mm x 100 mm x 68 mm | |
*s: solid wire; st: stranded wire; f: with ferrule
| Ordering information | |
|---|---|
| EL3356 | EtherCAT Terminal, 1-channel analog input, measuring bridge, full bridge, 16 bit | 
| ES3356 | EtherCAT Terminal, 1-channel analog input, measuring bridge, full bridge, 16 bit, plug-in wiring level | 