The EPP6228 IO-Link module enables connection of up to eight IO-Link devices. These can be IO-Link box modules, actuators, sensors or combinations of both. Point-to-point connection between the module and the connected device. The EtherCAT P Box is parameterized via the EtherCAT master. IO-Link is designed as an intelligent link between the fieldbus level and the sensor, wherein parameterization information can be exchanged bidirectionally via the IO-Link connection. The parameterization of the IO-Link devices with service data can take place from TwinCAT via ADS or, very conveniently, via the integrated IO-Link configuration tool. In addition to the IO-Link channels, the EPP6228 features eight digital inputs on pin 2 of the respective M12 socket.
In the standard setting, the eight IO-Link channels of the EPP6228-0022 operate as a 8-channel input module, 24 V DC, which if necessary communicates with connected IO-Link devices, parameterizes them and, if required, changes their operation mode. Each IO-Link port can also optionally be used just as an input or output.
Product status:
regular delivery
Product information
| Technical data | EPP6228-0022 |
|---|---|
| Protocol | EtherCAT |
| Bus interface | M8 socket, P-coded, shielded |
| Data transfer rates | 4.8 kbaud, 38.4 kbaud and 230.4 kbaud |
| Number of inputs | 8 additional digital inputs (each on pin 2) |
| Nominal input voltage | 24 V DC (-15%/+20%) |
| Input filter | 10 µs |
| “0” signal voltage | -3…+5 V |
| “1” signal voltage | 11…30 V (EN 61131-2, type 3) |
| Input current | typ. 3 mA (EN 61131-2, type 3) |
| Specification version | IO-Link V1.1, Class A |
| IO-Link interfaces | 8 |
| Nominal voltage | 24 V DC (-15%/+20%) |
| Distributed clocks | yes |
| IO-Link sensor supply L+ | 24 V DC, 1.4 A per port, ∑ 3.0 A for 8 ports |
| IO-Link extra power P24 | – |
| Current consumption from US | typ. 100 mA + load |
| Electrical isolation | 500 V |
| Weight | approx. 250 g |
| Operating temperature | -25…+60°C |
| Storage temperature | -40…+85°C |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. rating/installation pos. | IP65/66/67 (conforms to EN 60529)/variable |
| Approvals/markings | CE, UL |
| Housing data | 16 x M8, 8 x M12 |
|---|---|
| Dimensions (W x H x D) | 60 mm x 126 mm x 26.5 mm |
| Material | PA6 (polyamide) |
| Installation | 2 fixing holes 3.5 mm diameter for M3; 2 fixing holes 4.5 mm diameter for M4 |