The AX5806 TwinSAFE component is an option card for the AX5000 servo drive series from 60 A to 170 A and enables the implementation of safety-relevant drive functions. These functions are controlled via FSoE by a TwinSAFE Logic-capable component.
Drive-integrated safety functions:
- stop functions (STO, SOS, SS1, SS2)
- speed functions (SLS, SSM, SSR, SMS) with up to 8 speeds
- position functions (SLP, SCA, SLI) with reference cams
- acceleration functions (SAR, SMA)
- rotating direction functions (SDIp, SDIn)
Suitable for AX5000 Servo Drives from 60 A to 170 A:
- AX5160-0000-0200 and -0202
- AX5172-0000-0200 and -0202
- AX5190-0000-0200 and -0202
- AX5191-0000-0200 and -0202
- AX5192-0000-0200 and -0202
- AX5193-0000-0200 and -0202
Product status:
regular delivery
Product information
| Technical data | AX5806 |
|---|---|
| Function | TwinSAFE option card |
| Drive profile | FSoE |
| Safe acceleration functions | Safe Maximum Acceleration (SMA), Safe Acceleration Range (SAR) |
| Safe rotating direction functions | Safe Direction positive (SDIp), Safe Direction negative (SDIn) |
| Safe speed functions | Safe Speed Range (SSR), Safely Limited Speed (SLS), Safe Speed Monitor (SSM), Safe Maximum Speed (SMS) |
| Safe position functions | Safely Limited Position (SLP), Safe CAM (SCA), Safely Limited Increment (SLI) |
| Safe stop functions | Safe Torque Off (STO), Safe Stop 1 (SS1), Safe Stop 2 (SS2), Safe Operating Stop (SOS) |
| Safety standard | EN ISO 13849-1:2015 (Cat. 4, PL e) and IEC 61508:2010 (SIL 3) |
| Realization STO | via FSoE |
| Approvals/markings | CE, cULus |
| Ambient temperature (operation) | 0…50°C |
| Material compliance | AX5806 |
|---|---|
| CAS No. | no |
| POP | compliant |
| RoHS | compliant without exemption |
| China-RoHS | www.beckhoff.com/china-rohs-motion |
| CA Prop65 | www.beckhoff.com/prop65 |
| Disclaimer | This statement and the information contained above are, to the best of our knowledge and belief, accurate, based on the information we have received from our suppliers. This information is in line with the current standard of technology and our suppliers’ technical documentation. The absence of the substances is not verified by Beckhoff Automation by means of analytical tests. When addressed to our customers any information contained in this document is subject to the terms and conditions expressed in the governing customer agreement. Our general terms and conditions apply. |