ZK4721-0410-2xxx | Resolver extension cable 0.25 mm² with M12 plug for motors with resolver, drag-chain suitable

flexible, drag-chain suitable cable,

3 x 2 x 0.25 mm²

suitable for:

  • ZK4724-0410-2xxx

Product status:

regular delivery

Product information

Technical dataHead A
Shieldingyes
Installation sizeM12
Connector typesocket
Contact typefemale
Number of positions (face)8-pin
CodingA‑coded
Rated current2 A at 40°C (according to IEC 61076-2-101)
Rated voltage30 V (according to IEC 61076-2-101)
Recommended torque, nut0.6 Nm
Mating cycles≥ 100 (according to IEC 60512-9a)
Technical dataHead B
Shieldingyes
Installation sizeM12
Connector typeplug
Contact typemale
Number of positions (face)8-pin
CodingA‑coded
Rated current2 A at 40°C (according to IEC 61076-2-101)
Rated voltage30 V (according to IEC 61076-2-101)
Recommended torque, nut0.6 Nm
Mating cycles≥ 100 (according to IEC 60512-9a)
Technical dataCable by meter
Operating voltage≤ 300 V AC
Cross-section3 x 2 x 0.25 mm² (AWG24)
Usedrag-chain suitable
Material jacketPUR (polyurethane)
Outer cable diameter6.6 mm ± 0.2mm (0.259" ± 0.0079")
Min. bending radius, fixed installation5 x outer cable diameter
Max. number of cycles2 million
Jacket colorgreen

For further technical details, please refer to the data sheet.

A144.00 mm
B144.00 mm
Ordering informationLength
ZK4721-0410-20101.00 m
ZK4721-0410-20202.00 m
ZK4721-0410-20303.00 m
ZK4721-0410-20505.00 m
ZK4721-0410-210010.00 m
ZK4721-0410-215015.00 m
ZK4721-0410-220020.00 m

Further length on request

Material complianceZK4721-0410-2xxx
CAS No.7439-92-1
REACH SVHCLead
REACH Annex XVIIcompliant
REACH Annex XIVcompliant
POPcompliant
RoHScompliant with exemption
RoHS exemption6c: Copper alloy with a mass fraction of up to 4% lead
China-RoHSwww.beckhoff.com/china-rohs-io
CA Prop65www.beckhoff.com/prop65
DisclaimerThis statement and the information contained above are, to the best of our knowledge and belief, accurate, based on the information we have received from our suppliers. This information is in line with the current standard of technology and our suppliers’ technical documentation. The absence of the substances is not verified by Beckhoff Automation by means of analytical tests. When addressed to our customers any information contained in this document is subject to the terms and conditions expressed in the governing customer agreement. Our general terms and conditions apply.
Material compliance | SCIPSCIP No.
ZK4721-0410-2010d2a541c1-2124-4936-a17b-3d907595106e
ZK4721-0410-202091d7b8f7-a435-495e-a9ea-324ef3f7f332
ZK4721-0410-203039468bbc-6acf-4acc-98a7-7b4550349f5d
ZK4721-0410-20500113d3b7-7c9f-46a4-ac89-56c651d9db7c
ZK4721-0410-21004da66002-dd89-4329-a61b-c7359696f2ab
ZK4721-0410-2150ffe7af4a-f50d-4972-8d9c-9dd8717b5106
ZK4721-0410-2200aef9cff3-be94-4bc0-a771-98992d184d72

Loading content ...

© Beckhoff Automation 2026 - Terms of Use