ELM3002-0205 | EtherCAT Terminal, 2-channel analog input, voltage, ±60 V…±1200 V, 24 bit, 50 ksps, electrically isolated, 4 mm socket

ELM3002-0205 | EtherCAT Terminal, 2-channel analog input, voltage, ±60 V…±1200 V, 24 bit, 50 ksps, electrically isolated, 4 mm socket

ELM3002-0205 | EtherCAT Terminal, 2-channel analog input, voltage, ±60 V…±1200 V, 24 bit, 50 ksps, electrically isolated, 4 mm socket

Run LED
OK-LED Channel 1
OK-LED Channel 2
Channel 1
Channel 2
Top view 
ELM3002-0205 | EtherCAT Terminal, 2-channel analog input, voltage, ±60 V…±1200 V, 24 bit, 50 ksps, electrically isolated, 4 mm socket

ELM3002-0205 | EtherCAT Terminal, 2-channel analog input, voltage, ±60 V…±1200 V, 24 bit, 50 ksps, electrically isolated, 4 mm socket

The ELM3002-0205 EtherCAT Terminal of the basic series is designed for high-voltage measurement on batteries and generators and supports the measuring ranges 60/120/500 and 1200 V. The measuring range is selected in the CoE, as are the other setting options such as the filter parameters. Irrespective of the signal configuration, all ELM modules have the same technological properties. The ELM3002-0205 with oversampling offers a maximum sampling rate of 50,000 samples per second. The terminal is equipped with 4 mm lab jacks.

This terminal is also available as a variant with an individual calibration certificate. (See related products)

Extensive documentation is available from Beckhoff sales, support or measurement@beckhoff.com.

This ELM3xxx series measurement terminal enables efficient implementation of complex system-integrated data acquisition systems (DAQ) that place high demands on measurement accuracy and time synchronization.

Product status:

regular delivery

Product information

System dataELM300x
Voltage measurement±1200/600/360/60 V
Technical dataELM3002-0205
Number of channels2
Technologyvoltage measurement
Signal typedifferential
Connection technology2-wire
Connection type4 mm laboratory plug, service plug 1-pin
Max. sampling ratemax. 20 µs/50 ksps (per channel, simultaneously)
Oversampling factorn = 1…100 selectable
Internal resistancetyp. > 10 MΩ
Measurement error/ uncertaintytyp. < ±200 ppm/±0.02% in some measuring ranges, relative to the respective full scale value (DC), see documentation
Temperature coefficientup to typ. < 10 ppm/K in some measuring ranges, see documentation
Functional diagnosticsyes
Connection diagnosticsbroken wire/short circuit
Distributed clocksyes, accuracy << 1 µs
Resolution24 bit (incl. sign)
Electrical isolation channel/channel6 kV DC (unit test)
Electrical isolation channel/bus6 kV DC (unit test)
Electrical isolation channel/SGND6 kV DC (unit test)
Current consumption E-bustyp. 350 mA
Weightapprox. 350 g
Operating/storage temperature0…+55°C/-25…+85°C
Thermal dissipationtyp. 3 W
Special featuresExtendedRange 107%, free numeric filter, TrueRMS, integrator/differentiator, non-linear scaling, PeakHold
Approvals/markingsCE, UL
Housing dataELM-30-xpin
Design formmetal housing with signal LEDs
Materialzinc die-cast
Dimensions (W x H x D)30 mm x 100 mm x 95 mm
Installationon 35 mm DIN rail, conforming to EN 60715 with lock
Side by side mounting by means ofdouble slot and key connection
Marking
Wiringtouch-protected 4 mm plug (laboratory plug, banana plug)
Connection cross-sections*: 0.2…1.5 mm²,
st*: 0.2…1.5 mm²,
f*: 0.25…0.75 mm²
Connection cross-section AWGs*: AWG24…14,
st*: AWG24…14,
f*: AWG24…14
Stripping length8…9 mm