MelepaskanMemperbaikiTutup

Kantor Perwakilan Indonesia

AKR Gallery West Office Tower, 17th Floor, Unit G
Jl. Panjang No.5, Rt.11/Rw.10, Kebon Jeruk
Jakarta 11530, Indonesia

+62 21 2212-7044
sales@beckhoff.co.id
www.beckhoff.com/id-id/

EPP9001-0060 | EtherCAT P/EtherCAT connector, with power transmission

EPP9001-0060 | EtherCAT P/EtherCAT connector, with power transmission

EPP9001-0060 | EtherCAT P/EtherCAT connector, with power transmission

EtherCAT P signal input
EtherCAT signal output
Power supply status display:
Box supply (US)
Auxiliary voltage (UP)
1 | Tx+
2 | Rx+
3 | Rx-
4 | Tx-
1 | TX+/GNDS
2 | Rx+/GNDP
3 | Rx-/UP
4 | Tx-/US
1 | +24 V DC US
2 | +24 V DC UP
3 | GNDS
4 | GNDP
Top view 
Connector assignment 
EPP9001-0060 | EtherCAT P/EtherCAT connector, with power transmission

EPP9001-0060 | EtherCAT P/EtherCAT connector, with power transmission

EtherCAT P: The one cable solution – One step closer to automation without control cabinets

EtherCAT P: The one cable solution – One step closer to automation without control cabinets

The EPP9001-0060 EtherCAT P Box converts the incoming EtherCAT P signal (red M8 socket, P-coded) into an EtherCAT signal (green M8 socket). In addition, the voltage output from the US and UP voltages can be found on the EtherCAT P Box (black M8 socket). The EPP9001-0060 is an active EtherCAT device, i.e. it appears in the EtherCAT process image of the EtherCAT master, e.g. TwinCAT.

The EtherCAT P Box modules are characterized by their small and space-saving form factor.

Product status:

regular delivery

Product information

Technical dataEPP9001-0060
ProtocolEtherCAT P/EtherCAT
Bus interface1 x M8 socket, shielded, P-coded, 1 x M8 socket, shielded
Task within EtherCAT systemconverter from EtherCAT P to EtherCAT + power
Number of channelsIN: 1 x EtherCAT P, OUT: 1 x EtherCAT
Nominal voltage24 V DC (-15%/+20%)
Total currentfeed-in max. 3 A per US and UP
Current consumption from UStyp. 100 mA
Weightapprox. 90 g
Operating/storage temperature-25…+60°C/-40…+85°C
Vibration/shock resistanceconforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emissionconforms to EN 61000-6-2/EN 61000-6-4
Protect. rating/installation pos.IP65/66/67 (conforms to EN 60529)/variable
Approvals/markingsCE, UL
Housing dataEPPxxxx-006x
Dimensions (W x H x D)30 mm x 86 mm x 22 mm
MaterialPA6 (polyamide)
Installation2 fixing holes 3.5 mm diameter for M3

Loading content ...

Loading content ...

Loading content ...

Loading content ...

© Beckhoff Automation 2024 - Terms of Use