ZK1090-3161-1xxx | EtherCAT cable, PUR, AWG 22, drag-chain suitable

M8, plug, straight, male, 4-pin, A‑coded – M12, plug, straight, male, 4-pin, D‑coded

Plugs

Electrical data Head A Head B
Rated voltage 30 V (according to IEC 61076-2-101) 250 V
Rated current 4 A at 40 °C (according to IEC 61076-2-101) 4 A at 40 °C (according to IEC 61076-2-101)
Rated impulse voltage - 2.5 kV
Shielding yes yes
Contact resistance - < 5 mΩ
Insulation resistance ≥ 100 GΩ (according to IEC 60512) -
Mechanical data    
Installation size M8 M12
Connector type plug plug
Configuration straight straight
Contact type male male
Number of positions (face) 4-pin 4-pin
Coding A‑coded D‑coded
Recommended torque, nut 0.4 Nm 0.6 Nm
Mating cycles ≥ 100 ≥ 100 (according to IEC 60512-9a)
Way of locking screw screw
Weight per piece 0.028 kg (0.0617 lb) -
Body colour black black
Body material TPU, UL94 TPU, UL 94
Coupling nut material GD-Zn, Ni CuZn, Ni
Seal FPM FPM
Contact carrier colour green green
Contact carrier material PA 6, UL 94 V-0 PA, UL 94
Contact plating Ni, Au gal. Au
Contact material CuZn CuZn
Environmental data    
Special features halogen-free, flame-resistant as per IEC 60332-1-2, oil-resistant as per DIN EN 60811-2-1 -
RoHS compliant yes yes
Ambient temperature, operation -30…+70 °C, -22…+158 °F -30...+80 °C, -22...+176 °F
Protection class IP 67 in screwed condition (according to IEC 60529) IP 67 in screwed condition (according to IEC 60529)
Pollution level 3/2 (according to IEC 60664-1) 3/2 (according to IEC 60664-1)
Approvals - UL

Cable

Electrical data  
Rated voltage 600 V
Operating voltage ≤ 125 V (peak value, not for high voltage purposes)
Attenuation of shielding ≥ 40 dB
Insulation resistance ≥ 500 MΩ/km
Unbalanced capacitance to ground 1600 pF/km
Mutual capacitance 52 nF/km (1 kHz)
Characteristic impedance (Ethernet) 100 Ω ±15 Ω (100 MHz)
Loop resistance (Ethernet) ≤ 115 Ω/km
Differential impedance (Ethernet) 250 Ω/km
Unbalanced resistance (Ethernet) 2 %
Dielectric strength wire/wire (Ethernet) 1000 V DC/700 V AC
Dielectric strength wire/shield (Ethernet) 1000 V DC/700 V AC
Signal running time (Ethernet) 5.3 ns/m
Electrical parameters (Ethernet) based on CAT 5
Test voltage ≥ 2000 V
Mechanical data  
Cable structure (Ethernet) star quad
Conductor construction (Ethernet) 7 x 0.25 mm
Cross section (Ethernet) 0.34 mm² (AWG 22)
Min. bending radius, moved 7.5 x outer cable diameter
Min. bending radius, moved in drag chain 15 x outer cable diameter
Min. bending radius, fixed installation 5 x outer cable diameter
Weight 61 kg/km (41.0 lb/1000 ft)
Outer cable diameter 6.5 mm ± 0.2 mm (0.2559" ± 0.0079")
Conductor material (Ethernet) copper, tinned
Optical covering factor of shielding (Ethernet) ≥ 85 %
Use drag-chain suitable
Max. acceleration 4 m/s²
Max. speed 4 m/s
Max. number of cycles 3 million
Wall thickness of wire insulation (Ethernet) 0.375 mm
Jacket colour green
Material jacket PUR (polyurethane)
Wire colour code yellow, orange, white, blue
Wire insulation material PP (polypropylene)
Printing on the jacket BECKHOFF ZB9020 Industrial Ethernet
/ EtherCAT Trailing Cable * CAT5PLUS * 22AWG (SHIELDED) (UL) E119100 CMX 75°C VERIFIED (UL) CAT 5E PATCH CABLE FRNC *"length in meters"
Printing colour black
Environmental data  
Operation temperature range, moved -40…+70 °C, -40…+158 °F
Operation temperature range, fixed installation -20…+60 °C, -4…+140 °F
UV resistance yes
Oil resistance according to DIN EN 60811-404 (7x24 h/90 °C)
Acid, lye and solvent resistance depends on medium, concentration, temperature and duration
LABS-free yes
Flame-retardant yes
CFC-free yes
Halogen-free yes
Silicone-free yes
Approvals UL-Style AWM 20963
Attenuation  
Max. insertion loss
Frequency [MHz] 1 4 10 16 20 31.25 62.5 100
[db/100 m] 2.1 4.0 6.3 8.0 9.0 11.4 16.5 21.3
[db/100 ft] 0.6 1.2 1.9 2.4 2.7 3.5 5 6.5
Min. near-end crosstalk attenuation
Frequency [MHz] 1 4 10 16 20 31.25 62.5 100
[db/100 m] 80 76.0 70.0 65.0 63.0 60.0 55.0 50.0
[db/100 ft] 24.4 23.2 21.3 19.8 19.2 18.3 16.8 15.2
Contact assembly  
Dimensions  
 
 
A1 41.00 mm
B1 49.00 mm
B2 20.00 mm

Notes

- Depending on the cable length (L), the following length tolerances apply:

  0 m…<0.2 m: ± 10 mm | 0.2…4.0 m: + 40 mm | ≥ 4.0 m: + 1 %

- Illustrations similar

- Further cable length on request. The last three digits of the ordering information is the cable length in decimeters, e.g.ZKxxxx-xxxx-x020 = cable length 2.00 m

Ordering information Length
ZK1090-3161-1010 1.00 m
ZK1090-3161-1030 3.00 m
ZK1090-3161-1050 5.00 m
ZK1090-3161-1100 10.00 m
ZK1090-3161-1999 100.00 m

Beckhoff®, TwinCAT®, EtherCAT®, EtherCAT P®, Safety over EtherCAT®, TwinSAFE®, XFC® and XTS® are registered trademarks of and licensed by Beckhoff Automation GmbH. Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners.

 

© Beckhoff Automation GmbH & Co. KG 05/2019

 

The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual application do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressively agreed in the terms of contract.