ZK7A30-BY00-Axxx | B23, ENP cable, PUR, 3 G 4.0 mm² + 2 x 1.5 mm² + (1 x 4 x AWG22), drag chain suitable, key 3 (user-defined voltage), XTS

B23, flange rear assembly, straight, long, female+male, pins 4+PE+4, EtherCAT-coded – RJ45 + 5 x open end, 8-pin

Plugs

Electrical data Head A Head B
Rated voltage (Ethernet) 60 V DC 24 V DC
Rated current (Ethernet) 4 A at 40 °C 1.1 A at 30 °C
Rated voltage (power) 630 V AC / 850 V DC, 600V AC / DC (UL) -
Rated current (power) 28 A at 45 °C -
Rated impulse voltage (power) 6.0 kV -
Rated impulse voltage (Ethernet) 1.0 kV -
Voltage proof (contact/contact) 1.5 kV (power - Ethernet), 3.31 kV AC (power), 1.0 kV AC (Ethernet) -
Shielding (Ethernet) yes yes
Contact resistance < 10 mΩ (signal), < 5 mΩ (power) -
Insulation resistance ≥ 100 MΩ (according to IEC 60512) ≥ 10 GΩ (according to IEC 60512-2)
Mechanical data    
Installation size B23 RJ45 + 5 x open end
Connector type flange rear assembly -
Configuration straight, long -
Contact type female+male -
Number of positions (face) pins 4+PE+4 8-pin
Coding EtherCAT-coded -
Mechanical coding key 3 (user-defined voltage) -
Wire termination crimp connection -
Mating cycles ≥ 100 ≥ 750
Way of locking bayonet -
Weight per piece 0.200 kg (0.441 lb) -
Body colour - black
Body material - PC UL 94 V0
Flange housing material GD-Zn, Ni -
Seal NBR -
Contact carrier material PA, UL 94 -
Contact carrier colour (Ethernet) yellow -
Contact carrier colour (power) red -
Contact plating Au over Ni Au over Ni
Contact material copper alloy -
Environmental data    
Shock resistance 50 g (490 m/s²) conforms to IEC 60512-6c, 11 ms; 18 shocks per direction, 3 axes -
Vibration resistance 5 g (50 m /s²) conforms to IEC 60512-6d, 10 Hz. ... 500 Hz.; 10 cycles per axis; 6 h full duration -
RoHS compliant yes yes
Ambient temperature (operation) -30...+80 °C, -22...+176 °F -40...+85 °C, -40...+185 °F
Protection class IP 65/67 in screwed condition (according to IEC 60529) IP 20
Pollution level 3/2 (according to IEC 60664-1) -
Approvals UL 2237: File E484763 -

Cable

Electrical data  
Rated voltage (Ethernet) max. 300 V (peak value, not for high voltage purposes)
Rated voltage (power) 600 V
Attenuation of shielding ≥ 40 dB
Insulation resistance ≥ 500 MΩ/km
Unbalanced capacitance to ground 1600 pF/km
Mutual capacitance 52 nF/km (1 kHz)
Characteristic impedance (Ethernet) 100 Ω ±15 Ω (100 MHz)
Loop resistance (Ethernet) ≤ 115 Ω/km
Differential impedance (Ethernet) 250 Ω/km
Unbalanced resistance (Ethernet) 2 %
Dielectric strength wire/wire (Ethernet) 1000 V DC/700 V AC
Dielectric strength wire/shield (Ethernet) 1000 V DC/700 V AC
Signal running time (Ethernet) 5.3 ns/m
Electrical parameters (Ethernet) based on CAT 5
Test voltage ≥ 2000 V
Mechanical data  
Cable structure (Ethernet) star quad
Conductor construction (power) 19 x 0.30 mm
Conductor construction (Ethernet) 7 x 0.25 mm
Cross section (power) 3 x 4.0 mm² (approx. AWG12) + 2 x 1.5 mm² (approx. AWG16)
Cross section (Ethernet) 1 x 4 x 0.34 mm² (AWG 22)
Min. bending radius, moved 7.5 x outer cable diameter
Min. bending radius, fixed installation 5 x outer cable diameter
Outer cable diameter 6.5 mm ± 0.2 mm (0.2559" ± 0.0079")
Conductor material (Ethernet) copper, tinned
Shielding aluminium-clad foil, braiding of tinned copper wires
Optical covering factor of shielding (Ethernet) ≥ 85 %
Use drag-chain suitable
Max. acceleration 4 m/s²
Max. speed 4 m/s
Max. number of cycles 3 million
Wall thickness of wire insulation (Ethernet) 0.375 mm
Jacket colour green
Material jacket PUR (polyurethane)
Wire colour code Ethernet: white, yellow, blue, orange Power: brown, blue, white, green/yellow Signal: red, black
Wire insulation material PP polypropylene (Ethernet), PPE polyphenyl ether (Power)
Printing on the jacket BECKHOFF ZB9020 Industrial Ethernet
/ EtherCAT Trailing Cable * CAT5PLUS * 22AWG (SHIELDED) (UL) E119100 CMX 75°C VERIFIED (UL) CAT 5E PATCH CABLE FRNC *"length in meters"
Printing colour black
Environmental data  
Operation temperature range, moved -40…+70 °C, -40…+158 °F
Operation temperature range, fixed installation -20…+60 °C, -4…+140 °F
UV resistance yes
Oil resistance according to DIN EN 60811-2-1
Acid, lye and solvent resistance depends on medium, concentration, temperature and duration
LABS-free yes
Flame-retardant yes
CFC-free yes
Halogen-free yes
Silicone-free yes
Approvals UL-Style AWM 20963
Attenuation  
Max. insertion loss
Frequency [MHz] 1 4 10 16 20 31.25 62.5 100
[db/100 m] 2.1 4.0 6.3 8.0 9.0 11.4 16.5 21.3
[db/100 ft] 0.6 1.2 1.9 2.4 2.7 3.5 5 6.5
Min. near-end crosstalk attenuation
Frequency [MHz] 1 4 10 16 20 31.25 62.5 100
[db/100 m] 80 76.0 70.0 65.0 63.0 60.0 55.0 50.0
[db/100 ft] 24.4 23.2 21.3 19.8 19.2 18.3 16.8 15.2
Contact assembly  
Dimensions  
 
 
A1 42.50 mm
A2 30.00 mm
A3 23.80 mm
A4 37.50 mm
A5 M25
B1 43.80 mm

Notes

- Depending on the cable length (L), the following length tolerances apply:

0 m…3.0 m: + 100 mm | 3.0…10.0 m: ± 100 mm | ≥ 10.0 m: ± 2 %

- Illustrations similar

- Further cable length on request. The last three digits of the ordering information is the cable length in decimeters, e.g. ZKxxxx-xxxx-x020 = cable length 2.00 m

Installation dimensions  
Ordering information Length
ZK7A30-BY00-A010 1.00 m

Beckhoff®, TwinCAT®, EtherCAT®, EtherCAT G®, EtherCAT G10®, EtherCAT P®, Safety over EtherCAT®, TwinSAFE®, XFC®, XTS® and XPlanar® are registered trademarks of and licensed by Beckhoff Automation GmbH. Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners.

 

© Beckhoff Automation GmbH & Co. KG 07/2020

 

The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual application do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressively agreed in the terms of contract.